I tried changing the timeout and bytes to read settings, but still nothing changes. Just wire a False boolean constant to the ID Query terminal of the initialize vi to bypass this check. The pulse generator voltage is programmed as usual, but it gets all time control from the external signal input edges. Lastly, you don’t need to typecast the raw data into an I32 then typecast to SGL real. Message 4 of 4. Let me know how you get on.

Uploader: Daijas
Date Added: 23 April 2016
File Size: 22.43 Mb
Operating Systems: Windows NT/2000/XP/2003/2003/7/8/10 MacOS 10/X
Downloads: 92269
Price: Free* [*Free Regsitration Required]

agilent a – Discussion Forums – National Instruments

I looked in the manual at the frequency, period setting functions and the index. Sep 1, 6. This site uses cookies to offer you a better browsing experience. Sep 1, lqbview. As I compare the value read directly from the instrument. Is this wrong to do? However, LabVIEW Plug and Play instrument drivers are distributed with their block diagram source code, so you can customize them for a specific application.

  FUJI XEROX 2060 DRIVER DOWNLOAD

How to program a Pulse generator

This what I can see on MAX: Sep 3, The Action VIs – initiate or terminate test labvieew measurement operations, such as arming the trigger system or generating a stimulus. I made sure to press Save.

Auto-suggest helps you quickly narrow down your search results by suggesting possible matches as you type. Let me know how you get on. If you hit a piezo structure with a hammer, or a single pulse, it will ring at it’s resonant frequency. Sep 1, 3. The format for the block data per Keysight is: You don’t want to terminate the read prematurely.

I’d agi,ent this a go and see how you get on Accepted by topic author Liira. EXT-IN becomes the input to the pulse generator. The fastest way to get up and running with your instrument driver is to open one of the pre-built examples.

Message 5 of First, you don’t hard code the number of bytes to read i. Auto-suggest helps you quickly narrow down your search results by suggesting possible matches as you type. You can go directly to SGL. Your name or email address: Everyone who loves science agilwnt here! The Status VIs obtain the current status of the instrument or the status of pending operations. Here is how I would do a block transfer. Log 81144a or Sign up.

  MUSTEK 600CP SCANNER DRIVER DOWNLOAD

Why cannot I Enable Agilent ? Generally, you need to call the Initialize VI only once at the beginning of an application. Message 4 of 4. However, when trying to run the plug-and-play examples, this error occurs “The ID Query failed.

Finally, the Simple Error Handler is called which indicates whether an error occurred.